Equipment
Take a look at all our machines available for flow cytometry.
The facility currently operates:
Analyzers
- FACS-Symphony A1 (4 laser V-B-Y-R, 16 fluorescent detectors)
 - FACS-Symphony A3 (5 laser UV-V-B-Y-R, 23 fluorescent detectors)
 - FACS-Symphony A5 (5 laser UV-V-B-Y-R, 28 fluorescent detectors)
 - Agilent Penteon (5 laser UV-V-B-Y-R, 30 fluorescent detectors)
 - Cytek Aurora Spectral Analyzer (5 laser UV-V-B-Y-R, 64 total detectors - 40 color capable)
 
Sorters
- FACSAria for high-speed cell sorting (4 lasers V-B-O-R, 13 fluorescent detectors)
 - FACSAria for high-speed cell sorting (5 lasers UV-V-B-Y-R, 15 fluorescent detectors)
 - Cytek Aurora Spectral Sorter (5 laser UV-V-B-Y-R, 64 total detectors - 40 color capable) and is housed in a biosafety cabinet
 - S8 Imaging Sorter (5 laser UV-V-B-Y-R, 78 total detectors - 40 color capable) and is housed in a biosafety cabinet
 
Additional equipment details
Analyzers
For self-run flow cytometery.These machines typically require a 1-2 hour long training before new users are ready to run flow.
LSRII       | The BD LSRII is a 4 laser system (405, 488, 561 & 637 nm) with 13 fluorescent detectors. Runs 5ml polystyrene tubes or a HTS unit can be attached allowing the use of various 96 or 384 well plates.  | 
Symphony A1 
  | The BD Symphony A1 is a 4 laser system (405, 488, 561 & 637 nm) with 16 fluorescent detectors. Runs 5ml polystyrene tubes or a HTS unit is attached allowing the use of various 96 or 384 well plates.  | 
Symphony A3 
  | The BD Symphony A3 is a 5 laser system (355, 405, 488, 561 & 637 nm) with 23 fluorescent detectors. Runs 5ml polystyrene tubes only.  | 
Symphony A5 
  | The BD Symphony A5 is a 5 laser system (355, 405, 488, 561 & 637 nm) with 28 fluorescent detectors. Runs 5ml polystyrene tubes or a HTS unit is attached allowing the use of various 96 or 384 well plates.  | 
Penteon 
  | The Agilent Penteon is a 5 laser system (349, 405, 488, 561 & 637 nm) with 30 fluorescent detectors. An attached plate loader accommodates various plates (including deep well) and tubes (1.5 and 5ml 40 tube racks).  | 
Aurora 
  | The Cytek Aurora is a 5 laser spectral analyzer (355, 405, 488, 561 & 640 nm) with 64 total detectors (40 color panel). Runs 5ml tubes or an attached plate loader accommodates various plates.  | 
Sorters
For staff-run or self-run cell sorting.These machines can be booked by anyone for staff-run sorting, five days a week.
Sorter training is available for self-use by may require several training sessions.
Aria II (594) 
  | A 4 laser system with 12 fluorescent detectors and 4 way and plate sorting capability. Has 405 nm, 488 nm, 594 nm, and 633 nm lasers. For 4-way sorting, 1.5 ml or 5 ml tubes can be used while 2-way sorting can accommodate 15 ml tubes. Multi-well plates (6, 24, 96, or 384) with index sorting is also available. Sample and collection block can be chilled or warmed. Available nozzle sizes include; 70, 85, 100 and 130 µm. Researchers who have completed BD analyzer training can be trained to self-sort on the Aria, if desired.  | 
Aria II (561) 
  | A 5 laser system with 15 fluorescent detectors and 4 way and plate sorting capability. Has 355, 405, 488, 561, and 635 lasers. For 4-way sorting, 1.5 ml or 5 ml tubes can be used while 2-way sorting can accommodate 15 ml tubes. Multi-well plates (6, 24, 96, or 384) with index sorting is also available. Sample can be chilled or warmed during the sort. Available nozzle sizes include; 70, 85, 100 and 130 µm. Researchers who have completed BD analyzer training can be trained to self-sort on the Aria, if desired.  | 
Aurora CS 
  | The Cytek Aurora CS is a 5 laser spectral sorter (355, 405, 488, 561 & 640 nm) with 61 fluorescent detectors (40 color panel). For 6-way sorting, 1.5ml tubes can be used while 5ml tubes can be used for 4-way sorting and 15ml tubes can be used for 2-way sorting. 96-well plates with index sorting is also available. The sample can be warmed or cooled during sorting.  | 
The BD S8 is a 5 laser imaging/spectral sorter (355, 405, 488, 561 & 640 nm) with 78 fluorescent detectors (40 color panel). The 488nm laser has three fluorescent detectors as well as side-scatter, forward-scatter and lightloss. For 6-way sorting, 1.5ml or 5ml tubes can be used. 15ml tubes can be used for 2-way sorting. There is also an non-uniform tube holder. 96-well plates with index sorting is also available. The sample can be cooled during sorting.  | 